What Equipment Is Used For HALT?

HALT Chambers

Figure 1 - DES’s HALT Chambers
Figure 1 – DES’s HALT Chambers

Specialized test chambers are needed to perform a HALT. Typical HALT chambers are shown in Figure 1. The specification for HALT chambers is typically the following:

Liquid nitrogen (LN2) is used to cool the air temperature in HALT chambers. This allows for very rapid temperature changes of 60°C per minute and a cold temperature extreme of -100°C.

HALT chamber heating is provided by high power resistive heating elements that can produce changes of 60°C per minute and a hot temperature limit of +200°C.

Continue reading What Equipment Is Used For HALT?

Share This:

What Is A Typical HALT Procedure?

HALT procedures vary from lab to lab but are typically performed similar to DES’s procedure which is summarized below. DES’s HALT procedure is divided into 5 Stages: Stage 1 – Temperature Step Stresses, Stage 2 – Temperature Ramps, Stage 3 – Vibration Step Stresses, Stage 4 – Combined Temperature &Vibration Stresses, and Stage 5 – Temperature Destruct Limits.

Stage 1 is used to determine the HALT Operational Limits for temperature. The goal is not to cause destruction in Stage 1, but sometimes the operational and destruct limits occur simultaneously. The HALT Destruct Limits for temperature and vibration are typically found in Stages 3 to 5.

Temperature Step Stresses – Stage 1 (Figure 1)

Figure 1. Stage 1 Temperature Steps
Figure 1 – Stage 1 Temperature Steps

Continue reading What Is A Typical HALT Procedure?

Share This:

What Is HALT (Highly Accelerated Life Testing) And Why Perform HALT?

Highly Accelerated Life Testing (HALT) is a rigorous reliability test method that is used to expose product weaknesses. The goal of HALT is to proactively find weaknesses and fix them, thereby increasing product reliability. Because of its accelerated nature, HALT is typically faster and less expensive than traditional testing techniques.

HALT of circuit boards in one of DES’s HALT chambers
HALT of circuit boards in one of DES’s HALT chambers

HALT can be effectively used multiple times over a product’s life time. During product development, it can find design weakness when changes are much less costly to make. By finding weaknesses and making changes early, HALT can lower product development costs and compress time to market. When HALT is used at the time a product is being introduced into the market, it can expose problems caused by new manufacturing processes. When used after a product has been introduced into the market, HALT can be used to audit product reliability caused by changes in components, manufacturing or suppliers etc. The bottom line is that HALT can reduce product development time and cost, reduce warranty costs, improve customer satisfaction, gain market share, and increase profits.

Continue reading What Is HALT (Highly Accelerated Life Testing) And Why Perform HALT?

Share This:

Delserro Engineering Solutions Featured in Desktop Engineering

Delserro Engineering Solutions (DES) was honored to be featured in a recent article discussing the capabilities of engineering testing companies. The article highlighted the benefits, in terms of both design and cost, of adequately testing designs, preferably as early in the process as possible. It also discussed the ins and outs of partnering effectively with a reliability testing facility.

The goal of this article was to teach product developers how to get the most bang for their testing buck; a goal that aligns perfectly with DES’s philosophy. No matter what your testing needs are, be they HALT, HASS, or other environmental or stress tests, DES is able to help you design and implement the most comprehensive and accurate test possible. As always, our client’s success is the source of our satisfaction.

Continue reading Delserro Engineering Solutions Featured in Desktop Engineering

Share This:

How a HALT Test Shows The Future

Circuit Board HALT
HALT of Circuit Boards
Highly Accelerated Life Testing Procedures

Speeding up the process of device or circuit failure requires extreme inputs, those that are unlikely to occur during real-world use by customers regardless of the environment. Three common testing inputs are high and low temperatures, rapid cycling of the same and vibration along six-axes. In some cases, a highly accelerated life test (HALT) will incorporate combined temperature and vibration stresses. These inputs can result in component failure in the span of days, hours, or even minutes compared to months or years of typical usage.

 

Benefits of HALT Testing

While the percentages of failure based on the stress applied to a product can vary significantly, highly accelerated life testing can typically expose weaknesses faster than other means of testing. For example, of the above inputs, roughly two-thirds of failures will only come after the introduction of vibration alone or combined vibration and temperature tests. This means that during the product development process, a significant number of potential flaws would not be identified through testing that did not include these two stresses.

Continue reading How a HALT Test Shows The Future

Share This:

Recent Testing Projects

We had many interesting test projects at Delserro Engineering Solutions this past month:

  • We completed a Pyroshock test on our Mechanical Impact Pyroshock Simulator (MIPS) on equipment that will fly into outer space.
  • On the other end of the altitude spectrum, we completed environmental testing of components that will be used in submarines to MIL-E-917.  MIL-E-917 is a military specification for Naval shipboard electric power equipment.
  • In the middle of the altitude range, we performed combined temperature and vibration testing on sensors that will be used in automobile engines to specification GMW 3172.  GMW 3172 is a General Motors Specification for electronic component durability.

The following is a sample of some additional testing projects we have completed recently:

Share This:

An Informational Guide to HALT and HASS

Product reliability is essential to success in today’s competitive global market.  HALT and HASS are intensive methods used to expose and then improve design and process weaknesses.  HALT and HASS are faster, less expensive and more accurate than traditional testing techniques.  HALT and HASS are proven processes used to lower product development and manufacturing costs, compress time to market, reduce warranty costs, improve customer satisfaction, gain market share and increase profits. Some companies have reported savings in the millions after using HALT and HASS.

HALT and HASS can accelerate a product’s aging process from actual months into test minutes much faster than traditional testing!

Continue reading An Informational Guide to HALT and HASS

Share This:

Lead Free Solder Reliability Issues and Test Methods

This article discusses the reliability challenges of switching over to lead-free solder and the test methods used to demonstrate reliability, written by Gary Delserro and published in Evaluation Engineering Magazine.  Click on the link to download the article in PDF, Lead Free Solder Reliability Issues & Test Methods.

Environmentally friendly is a term rapidly invading the electronics industry.

The electronic industry will be facing great challenges over the next few years as the solder used in electronic products is migrating toward lead-free.  This is being driven by mandates in Europe such as Waste Electrical and Electronic Equipment (WEEE) and Restrictions of Hazardous Substances (RoHS) and similar ones in Japan.  There also is a great deal of pressure in the US to do the same.

Continue reading Lead Free Solder Reliability Issues and Test Methods

Share This:

Exposing Hard to Find Defects

This article discusses an abbreviated technique that uses the tools of HALT to expose hard-to-find defects in products returned by customers, written by Gary Delserro and published in Evaluation Engineering Magazine.  Click on the link to view the article in PDF, Exposing Hard to Find Defects.

How many times have your customers returned products or circuit boards with reported defects that you can’t find?  Every manufacturer experiences this situation at some time.  Your customer reports a problem in your product and sends it back to you.  You test the faulty product in your lab and the problem doesn’t occur. Sometimes you try to bend it or tap it against the table.  You may even try heating it in a chamber or with a heat gun or using a freeze spray.  Still the problem does not expose itself.

Continue reading Exposing Hard to Find Defects

Share This: